top of page
digital-technology-abstract-cyberspace-network-science-communication-cyber-circuit-system-

Our Sites

Mega DC is currently planning, building and operating number of
AI Data Center projects in Israel.
In addition, our group owns vast land reserves with secured power
on several sites country wide.  

>

Modiin

Site name / Location

Total Power

Size (SQM)

KW per Rack

MDCIL-1 
Modiin

20 MW

15 K

Up to 1MW

Tier design

Substation Onsite

Liquid Cooling Support (Y/N)

RFS

T3

Y

Operational

Additional information

10MW are under construction, with RFS in 2026.

modiin
Masmia

Site name / Location

Total Power

Size (SQM)

KW per Rack

MDCIL-2
Masmia (200)

40 MW

20 K

Up to 1MW

Tier design

Substation Onsite (Y/N)

Liquid Cooling Support (Y/N)

RFS

T3

Y

Y

2026

Additional information

MATAM Haifa

Site name / Location

Total Power

Size (SQM)

KW per Rack

MDCIL-3
MATAM Haifa

20 MW

14 K

Up to 1MW

Tier design

Substation Onsite

Liquid Cooling Support (Y/N)

RFS

T3/T4

Y

2027

Additional information

Within MATAM Haifa High-Tec Park, 500m from subsea cables landing point

20MW are under construction, with RFS of 10MW in 2027.

Beit Shemesh.jpg

Site name / Location

Total Power

Size (SQM)

KW per Rack

MDCIL-4
Beit Shemesh (Campus)

240 MW

115 K

Up to 1MW

Tier design

Substation Onsite

Liquid Cooling Support (Y/N)

RFS

T3/T4

Y

Y

2027

Additional information

120MW are under construction, with RFS of 60MW in 2027.

idan hanegev.jpg

Site name / Location

Total Power

Size (SQM)

KW per Rack

MDCIL-5
Idan Hanegev
(Campus)

180 MW

75 K

Up to 1MW

Tier design

Substation Onsite

Liquid Cooling Support (Y/N)

RFS

T3/T4

Y

Y

2028

Additional information

60MW are under construction, with RFS in 2027.

data center

Site name / Location

Total Power

Size (SQM)

KW per Rack

MDCIL-6
Masmia (502)

TBD

46 K

Up to 1MW

Tier design

Substation Onsite

Liquid Cooling Support (Y/N)

RFS

T3/T4

Y

Y

TBD

Additional information

data center

Site name / Location

Total

Power

Size (SQM)

KW per Rack

MDCIL-7
Masmia (201)

TBD

20 K

Up to 1MW

Tier design

Substation Onsite

Liquid Cooling Support (Y/N)

RFS

T3/T4

Y

Y

TBD

Additional information

data center

Site name / Location

Power

Size (SQM)

KW per Rack

MDCIL-8
Hadera (Campus)

TBD

180 K

Tier design

Substation Onsite

Liquid Cooling Support (Y/N)

RFS

Y

TBD

Additional information

1KM away from 2.6GW "Orot Rabin" Power plant

0.3KM away from another 800MW privately owned Power plant 

bottom of page